colibri-page-builder
domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init
action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/quant216/public_html/wp-includes/functions.php on line 6114Quantec is a world leader in the acquisition of MT data. We have focused on collecting the best possible deep data for our clients through the development of MT receivers and the continuous improvement approach to data acquisition\n methodologies.<\/p>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n
One of the most sophisticated and accurate surveys for providing surface to depth resistivity imaging for a variety of regional, local and remote applications.<\/p>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n
SPARTAN MT is a robust, full-tensor audio-magnetotelluric technology that acquires high quality data in the 10 kHz to 0.001 Hz frequency band. Data are presented as resistivities and correlate with geology, structure and potential geothermal reservoirs. Quantec\u2019s SPARTAN MT system provides a unique and effective method for obtaining deep resistivity over a variety of terrains. With high portability and flexible deployment, SPARTAN MT is environmentally friendly and non-invasive. Depth of investigation is from surface to 10,000 m and beyond.<\/span><\/p>\n Proven expertise in MT acquisition enables Quantec to deliver premium-quality data and effective interpretations that accurately map resistivities to depth. The SPARTAN systems are deployed globally, in both MT and DCIP modes, to provide clients with unique configurations tailored to challenging environments where deep imaging and high-quality data are required.<\/span><\/p>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n MT (Magnetotellurics) is a passive electromagnetic technique that maps resistivity by measuring the telluric currents induced in the earth by natural sources: lightning, solar flares, and ionospheric resonances. MT infers the\n earth’s subsurface electrical properties from measurements of natural electric and magnetic fields at the earth’s surface. SPARTAN MT is a 10-channel, 24-bit data acquisition system (see diagram below); at each MT site, 10 channels\n are run simultaneously and can collect 6 magnetic fi\u00adeld measurements. Spartan MT uses 3 high-frequency (HF) and 3 low-frequency (LF) coils for maximum sensitivity and the highest quality data possible. By measuring full\n tensor data in the 10 KHz to.001 Hz frequency band, investigation depth ranges from near surface down to 10 km or more can be achieved by the system.<\/p>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n Resistivity section derived from MT data collection. 2D section shown to 1500 metres<\/p>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n SPARTAN MT can be deployed in a number of configurations depending on your exploration requirements. Depending on the exploration initiative and budget, SPARTAN can be deployed in transects to collect 2D information or in some cases\n large grid patterns or even random deployment locations, that can accommodate harsh topography, geology, culture etc., may be used to acquire 3D data sets. The data is easily integrated with other data types to enhance interpretations.\n High quality data \u2013 full-tensor measurement provides sensitivity and accuracy. The Quantec system is very portable and rugged. Depending on the configuration an MT site may involve a set up as shown below.<\/p>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n Portable system for rapid deployment<\/p>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n SPARTAN MT survey plan, site locations with excluded sections in red<\/p>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n Shallow (0-1000m) exploration \u2013 tight station spacing (~200 m), high frequency AMT (Audio band Magnetotellurics) recording<\/p>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n Regional target evaluation and exploration \u2013 wide station spacing (500m \u2013 1000m), low frequency recording<\/p>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n \n
\n
\n
Flexible <\/strong>survey design and high quality data acquisition<\/h3>\n <\/div>\n <\/div>\n
\n
\n
When to use SPARTAN MT<\/strong>?<\/h2>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n <\/div>\n